Adjusting the tripping force of the decentralised overload safety
REQUIREMENTS
The implement is coupled.
Blue hydraulic connection is coupled.
WARNING
WARNING
- Couple hydraulic operating unit 1 on tractor control unit.
- Connect the hydraulic operating unit to the hydraulic accumulator of the overload safety.
- Take hand lever out of the tool box and fit it on the hydraulic accumulator.
- Open the hydraulic accumulator with the hand lever.
To adjust the tripping force of the overload safety for the respective plough body,
Actuate the blue tractor control unit.- Select preload between 100 bar and 170bar.
Default value: 120bar
- Close the hydraulic accumulator with the hand lever.
- Depressurise hydraulic operating unit.
- Disconnect the hydraulic operating unit from the hydraulic accumulator.
- Adjust all hydraulic accumulators of the overload safety the same way.
- Then return the hand lever to the transport box.