Rectifying faults
Back
Handling error messages
Troubleshooting
F45001 Speed of the metering motor is too low, drive faster.
F45002 Speed of the metering motor is too high, drive slower.
F45003 Setpoint of the fertilizer metering unit cannot be maintained.
F45004 Overcurrent on the output: fertilizer metering unit. Check actuator(s) and wiring harness!
F45005 Opto-sensor in the following row is dirty: X.
F45006 Setpoint of the fertilizer metering unit cannot be maintained.
F45007 Setpoint of the fertilizer metering unit cannot be maintained.
F45008 Setpoint of the fertilizer metering unit cannot be maintained.
F45009 Target fan speed cannot be maintained.
F45011 The following software version is not compatible: ...
F45014 Insufficient supply voltage
F45020 Sensor error: loading board. Check sensor and wiring harness
F45021 The following hopper is empty: Seed
F45023 The terminal can process fewer target rates than provided by the implement. Adjust the ISOBUS settings of the implement.
F45024 Seed line in the following row is clogged: X.
F45034 Target fan speed of fan 1.1 cannot be maintained.
F45035 Sensor error: XA.B12 low level sensor fertilizer left. Check sensor and wiring harness.
F45036 Sensor error: XA.B12 low level sensor fertilizer 2. Check sensor and wiring harness
F45039 Sensor error: XA.B37 track marker. Check sensor and wiring harness.
F45040 Sensor error: XA.B73 coulter pressure. Check sensor and wiring harness
F45042 Sensor error: XA.S01 calibration button. Check sensor and wiring harness.
F45046 Section Control cannot be activated! The following conditions must be met: 1. Section Control must be activated on the terminal (Task Controller) 2. Implement must be working faultlessly.
F45047 Section Control has been deactivated!
F45051 (A to H) Internal opto-sensor error in the following row: X.
F45052 GPS recording not possible! The following conditions must be met: 1. Implement must be stopped 2. Fan must be switched off.
F45053 Micropellet metering unit in the following row is not responding: X.
F45054 Micropellet metering speed is too low, drive faster.
F45055 Micropellet metering speed is too high, drive slower.
F45056 Sowing not possible! The following conditions must be met: 1. Metering unit must be switched on 2. Fan must be switched on.
F45057 Minimum fan speed not reached, metering unit stopped!
F45058 Selected source for forward speed not available! Select available source!
F45061 Setpoint value of the micropellet metering unit cannot be maintained
F45062 Minimum pressure not reached
F45063 Maximum pressure exceeded
F45064 Sensor error: XA.B31 fan pressure. Check sensor and wiring harness
F45065 Sensor error: fan speed. Check sensor and wiring harness
F45066 Maximum fan speed exceeded
F45067 The following scraper did not reach the position: X.
F45068 Angle sensor for the following scraper has failed: X.
F45069 Overcurrent on the output of the micropellet metering unit in the following row: X. Check actuator(s) and wiring harness!
F45070 Overcurrent on the metering unit outlet in the following row:
F45071 Singling unit in the following row does not respond: X.
F45072 No product flow detected in the following row: X.
F45074 Target spread rate not reached in the following row: X.
F45075 Target spread rate was exceeded in the following row: X.
F45076 Singling unit metering speed is too low, drive faster.
F45077 Singling unit metering speed is too high, drive slower.
F45078 The following participant is missing: ....
F45080 Sensor error: folding monitoring.
F45081 Working position sensor for seed is faulty (index 0 - 23): Check sensor and wiring harness.
F45082 Sensor error: fertilizer hopper fan speed. Check sensor and wiring harness
F45083 Minimum fan speed of the fertilizer hopper not reached, metering unit has stopped!
F45084 Target fan speed of the fertilizer hopper cannot be maintained.
F45085 Maximum fan speed of the fertilizer hopper exceeded.
F45087 Due to overload the fertilizer metering unit switches off
F45088 Micropellet metering unit switched off due to overload on the following row: X. Check motor
F45089 Seed motor switched off due to overload in the following row: X. Check motor and singling unit.
F45090 The following participant was added: front hopper.
F45091 Contact force cannot be maintained
F45092 The soil is too soft! Less force cannot be exerted on the coulters!
F45093 The following participants are no longer available: fertilizer hopper.
F45094 The settings have been changed. The implement must be restarted.
F45095 Force sensor failed in following row: X. Check sensor and wiring harness
F45096 Left weigh cell has failed
F45097 Right weigh cell has failed
F45099 The following hopper is empty: Seed
F45100 The following fertilizer metering unit does not respond: X
F45101 Sensor error: seed fill level. Check sensor and wiring harness
F45102 Sensor error: micropellet fill level. Check sensor and wiring harness
F45103 Too many contact force sensors have failed. Regulation not possible.
F45104 Fewer contact force sensors detected than installed. Check coulter pressure regulation.
F45105 GPS tramline not possible. No communication with the terminal. No warranty for displaying the correct track number.
F45106 The terminal can process fewer placement points than provided by the implement.
F45107 Wrong direction of travel! Drive the track from the other side!
F45108 Working position sensor for fertilizer is faulty: Check sensor and wiring harness
F45109 Working position sensor for micro-granules is faulty: Check sensor and wiring harness
F45110 Selected source for sensor calibration not available.
F45113 Section Control not possible, the following flaps are faulty: X.Y.
F45114 Flap cannot reach its position – row XY.
F45115 Sensor values of following flaps outside of the measuring range: X.Y.
F45116 Calibration of following flaps failed: X.Y.
F45117 Calibration of following flaps failed; Section Control not possible: X.Y.
F45118 Sensor error: following flap: X.Y.
F45119 Configuration of the segment distributor head is not supported.
F45120 The following ECU has failed: X.Y.
F45121 Metering unit empty fertilizer 2.
F45122 Telescopic axle not retracted.
F45123 Sensor for the left section is defective
F45124 Sensor for the right section is defective.
F45125 Section end position cannot be reached.
F45126 Sensor for the position of the left telescopic axle has failed.
F45127 Sensor for the position of the right telescopic axle has failed.
F45128 Sensor for the left singling pressure has failed.
F45129 Sensor for the right singling pressure has failed.
F45130 Central Seed Supply: Sensor has failed.
F45131 Central Seed Supply: Increase pressure, singling pressure X mbar pressure difference X mbar.
F45132 Central Seed Supply: Reduce pressure, singling pressure X mbar pressure difference X mbar.
F45133 Check position of the flap for pressure distribution. Check singling pressure left X mbar – singling pressure right X mbar.
F45134 Insufficient voltage supply of the onboard generator. Check generator.
F45135 Function not possible! The following conditions must be met: 1. Implement must be stopped 2. Implement must be in working position 3. Minimum quantity must be reached
F45136 The following ECU has failed: X.Y.
F45137 Overcurrent on the output: Proportional valve of the section pressure. Check actuator(s) and wiring harness.
F45138 Sensor error: center weigh cell. Check sensor and wiring harness
F45139 Sensor error: XA.B13 low level sensor fertilizer right. Check sensor and wiring harness
F45140 Sensor error: metering unit fertilizer 2. Check sensor and wiring harness.
F45141 Supply voltage exceeded.
F45142 Overcurrent on the following metering unit: Fertilizer metering unit. Check actuator(s) and wiring harness.
F45143 Fertilizer metering unit switches off due to overload: Check motor(s)
F45144 The following hopper is empty: Micro-granule
F45145 Fertilizer unit 1 or agitator motor 1 does not respond
F45146 Sensor error: Low level sensor seed: Check actuator(s) and wiring harness
F45147 Sensor error: XA.B12 low level sensor micro-granules: Check actuator(s) and wiring harness
F45148 CCS pressure adjustment has failed
F45149 Central Seed Supply automatic mode is not possible. The following sensors and valves must be functioning faultlessly: Singling unit pressure sensors, Central Seed Supply pressure sensors, linear drive of the Central Seed Supply pressure regulation, fertilizer fan speed sensors, and singling unit.
F45150 The difference between CSS pressure and singling pressure cannot be maintained.
F45151 Hopper internal pressure sensor 1 has failed.
F45152 Hopper interior pressure 1 not reached
F45153 Yaw rate sensor has failed
F45154 Hopper internal pressure sensor 2 has failed.
F45155 Hopper interior pressure 2 not reached
F45156 Flap cannot reach its position: Row XY.
F45157 Setpoint of fertilizer metering unit 2 cannot be maintained
F45158 Metering motor fertilizer 2 does not respond
F45159 Error at speed detection FertiSpot portioner: Row XY
F45160 Stiffness detected: Row XY
F45161 FertiSpot failed: Row XY
F45162 FertiSpot motor does not respond: Row XY
F45163 FertiSpot speed is too high, drive slower.
F45164 FertiSpot working mode not possible
F45165 No FertiSpot ECUs available
F45166 Internal error FertiSpot ECU in the following row:
F45167 Connecting rod break detected: Placement point A: Row XY
F45171 Sensor error: Section pressure please check sensor and wiring harness!
F45172 CSS error linear drive
F45173 CSS actuator short-circuit
F45174 Sensor error: CSS pressure adjustment. Check sensor and wiring harness!
F45175 Speed of metering unit fertilizer 2 is too low, drive faster
F45176 Speed of metering unit fertilizer 2 is too high, drive slower
F45177 Sensor error: XA.B10 low level CSS.1. Check sensor and wiring harness
F45178 CSS unit 1 empty
F45179 FertiSpot angle sensor of the following row has failed: XY
F45180 Sensor error: track marker left. Check sensor and wiring harness
F45181 Sensor error: Track marker right. Check sensor and wiring harness
F45182 Sensor error: XA.2MK6 coulter pressure left. Check sensor and wiring harness
F45184 Sensor for the singling pressure has failed.
F45183 Sensor error: XA.2MK7 coulter pressure right. Check sensor and wiring harness
F45185 Metering unit empty fertilizer 1.2
F45185 Metering unit empty fertilizer 2.2
F45187 Sensor error: Low level sensor fertilizer 1.1. Check sensor and wiring harness
F45188 Sensor error: Low level sensor fertilizer 1.2. Check sensor and wiring harness
F45189 Sensor error: Low level sensor fertilizer 2.1. Check sensor and wiring harness
F45190 Sensor error: low level sensor fertilizer 2.2 check sensor and wiring harness.
F45191 The following metering unit is empty: XY
F45192 The following hopper is empty: XY
F45193 Sensor error: XA.B10 low level sensor fertilizer 1: Check sensor and wiring harness.
F45194 Sensor error: XA.B50 low level sensor fertilizer 2: Check sensor and wiring harness.
F45195 Metering motor 1.1 does not respond
F45196 Speed of metering unit fertilizer 1 is too high, drive slower
F45197 Speed of metering unit fertilizer 1 is too low, drive faster
F45198 Setpoint of the fertilizer metering unit cannot be maintained.
F45199 Metering motor fertilizer 1 does not respond
F45200 Sensor error: XA.B31 fan speed 1:1: Check sensor and wiring harness.
F45201 Sensor error: XA.B31 fan speed 1:2: Check sensor and wiring harness.
F45202 Minimum fan speed fan 1.1 not reached, metering unit stops
F45203 Load drop on the FertiSpot motor detected in the following row: XY
F45204 Metering motor fertilizer 1.2 does not respond
F45205 Metering motor fertilizer 2.1 does not respond
F45206 Metering motor fertilizer 2.2 does not respond
F45207 Maximum fan speed fan 1.1 exceeded
F45208 Minimum fan speed fan 1.2 not reached, metering unit stops
F45209 Excessive speed differential of the singling unit fan. Singling unit fan 1.1 left. Singling unit fan 1.2 right
F45210 Maximum fan speed fan 1.2 exceeded
F45211 Target fan speed cannot be maintained
F45212 ECU of track marker has failed
Operating Manual – ISOBUS Software Precea
Rectifying faults
Troubleshooting
F45066 Maximum fan speed exceeded
F45066 Maximum fan speed exceeded
The permissible fan speed is too high.
Reduce fan speed