Repositioning the fill level sensor
The fill level sensor must be attached at the suitable height, depending on the spreading material and the spread rate.
Grains and legumes: attach the fill level sensor in the upper holder or middle holder, depending on the spread rate.
Fine seed: attach the fill level sensor in the lower holder (factory setting).
Fertiliser: attach the fill level sensor in the upper or lower holder, depending on the spread rate.
Lower seed rates: at lower seed rates, the low level sensor of the metering unit can be used to receive notifications regarding low levels in the hopper at a later time.
If low spread rates should be metered:
Insert the fill level sensor in the lower mount 1.
If high spread rates should be metered:
Insert the fill level sensor in one of the upper mounts 1.
As soon as the fill level sensor is no longer covered, a warning message appears on the control terminal or control computer.
When the fill level sensor is inserted in the lower mount, the warning message appears very late.
- Make sure that the hopper is empty.
- Loosen the nuts on both sensor mounts 2.
- Pull the fill level sensor 3 out of the fill level sensor mount 1.
- Pull the sealing plug out of another fill level sensor mount.
- Insert the fill level sensor flush with the sensor mount in the desired fill level sensor mount.
- Insert the sealing plug in the empty fill level sensor mount.
- Tighten the nuts on both sensor mounts.