Checking the blades and blade mounts
WARNING
REQUIREMENTS
The PTO shaft drive is switched off.
- Open the rotor protective cover like for changing the blades, Changing or replacing the blades.
- Check the wear dimension A in the mounting area of the blade 1.
If the wear dimension is between 7mm and 10,2mm, the blades can still be used.
If the wear limit B of 7mm is undercut in the mounting area:
Replace the blade.
- Check the wear dimension A in the mounting area of the blade mounts 1.
If the wear dimension is between 6mm and 9mm, the blade mounts can still be used.
If the wear limit B of 6mm is undercut in the mounting area:
Replace the blade mount.- Check the bolted connections on the blade mounts for firm seating.
- Close the rotor protective cover like for changing the blades, Changing or replacing the blades.