Uncoupling the dual-circuit hydraulic brake system
To dissipate the pressure in the hydraulic accumulator:
Activate the emptying valve 1 for 5 seconds.
- Uncouple the CL brake line 1.
- Uncouple the SL supplemental line 2.
- Hook-in the lines on the hose cabinet.
- Release the locking mechanism 2.
- Unplug the ABS connector 1.
- Hook-in the ABS connector on the hose cabinet.