Checking the lower link pins

Interval

  • all 10 Operating hours

    or

    Daily

Criteria for visual inspection of the lower link pins:

  • Cracks

  • Fractures

  • Permanent deformations

  • Permissible wear: 2mm

  1. Check the lower link pins for the listed criteria.
  2. Replace worn pins.