Determining the calibration factor at a standstill

  1. Keep the spreading disc drive switched off.
  2. Remove the spreading discs.
  3. Install the calibration chute on the left spreading disc.
  4. Place a collection bucket underneath.
  5. Call up the Product menu.
  6. Select Other fertiliser settings.
  7. Call up the Calibration menu.
  8. Observe the implement operating manual.
  9. Select Continue.
  10. Take the calibration factor from the setting chart and enter it.
  11. Select Continue.
  12. Enter the intended speed.
  13. Enter the working width.
  14. Select Continue.
  1. Check the target spread rate.
  2. Select Continue.
  1. Switch on the spreading disc drive.
  2. Open the left shutter.
  3. When the collection bucket is full,

    close the left shutter.
  4. Switch off the spreading disc drive.


  5. Weigh the collected quantity.
  1. Enter the weight of the collected quantity.
  2. Select Continue.

The new calibration factor will be displayed.

  1. Save the calibration factor

or

To optimise the calibration factor,

repeat the calibration.