Cleaning the spray agent canister

NOTE
If you have operated the induction bowl with spray liquid, this means that the canister cleaning nozzle, the ring line and the spray gun are contaminated. Clean these components with flushing water before continuing with this procedure.
  1. Select on switch tap EB.
  1. On the TwinTerminal, select menu Induction bowl.
  2. Press the button for the desired source to supply the induction bowl.
  1. Open the hinged lid of the induction bowl.
  1. Press the canister opening onto the canister cleaning nozzle 1. Flush the spray agent canister for 15 seconds.
  2. To increase the water pressure for the canister cleaning nozzle:

    Select on the TwinTerminal.
  3. Press the canister opening onto the canister cleaning nozzle. Flush the spray agent canister with increased water pressure for 15 seconds.
  1. Set the spray agent canister in the receptacle 1 on the hinged lid and allow spray agent to drip out.
  1. On the TwinTerminal, select the active button for supply of the induction bowl.

The supply of the induction bowl will be interrupted.