Seed delivery interrupted
If the taker unit is contaminated, the air current is disrupted. This causes insufficient seed delivery into the singling unit.
- Deactivate all fans.
- Dismount the cover 2.
Pay attention to the seal in the cover.
- Take out the sieve 1.
- Clean the sieve with a brush.
- Insert the sieve in the taker unit.
- Mount the cover.
If the conveyor line is blocked, seed is not delivered into the singling unit.
- Set the pressure difference to 40 mbar.
- Bring the adjustment lever 1 into position 0.
The control flaps 2 open up the bypass 3.
The seed is delivered into the singling unit.
If the singling unit cannot take up enough seed to eliminate the blockage:
Empty the singling unit.- Repeat the flushing procedure until the blockage in the conveyor line is eliminated.
If the giver unit is blocked, seed will not be delivered into the singling unit.
- Deactivate all fans.
- Unscrew the knurled screw 1 and pivot it to the side.
- Pull the sliding shutter 3 out of its parking position.
The cover 2 is opened.
- Move the sliding shutter 1 into the seed giver unit 2.
The seed flow is interrupted for the desired side.
- Turn the lever 1 until the latch engages in the groove 5.
The desired emptying flap 2 remains closed.
- Turn the lever 3 into the center position.
The emptying flap 4 swings downward.
The seed that is present in the giver unit flows out.
- Collect the seed in a suitable container.
- Clean the giver unit.
When the giver unit is cleaned:
Swing the emptying flap 2 upwards.- Turn the lever 1 until the latches engage in the groove 3.
If other giver units are blocked:
Repeat the cleaning procedure.
- Close the cover 1.
- Pivot the knurled screw 2 in front of the cover and tighten it.
- Bring the sliding shutter 3 into parking position.