Checking and cleaning the distributor head
Interval
or
At the end of the season
- Unlock the locking lever 1 on the metering housing.
To prevent the accumulation of moisture:
Open the calibration flap 2.
A ladder is required to reach the distributor head.
To safely reach the distributor head:
Hand the ladder 1 with the first rung in the notch of the device 2.
CAUTION
- Climb up the ladder to the distributor head.
- Loosen and remove the 6 ring nuts 1.
- Take off the cover using the handle 2.
- Put the cover 1 in the holder 2.
NOTE
To remove the deposits:
Clean the corrugated tube 1 and the seed outlets 2 with compressed air.
To check the flaps for ease of movement:
Move the lever back and forth 1.
If the motor unit 3 or the connecting rod 4 are defective, the flaps can be fixed in the open or closed position with the bolt 2.
- Check the connecting rod 4 and motor unit 3 for damage.
If the connecting rod or motor unit are damaged:
Replace the connecting rod or motor unit.- Install the cover.
- Install the 6 ring nuts and tighten by hand.