Installing the battery

When the battery was removed to be stored protected from frost, it must be reinstalled for operation.

  1. Check the voltage of the battery at rest.

Voltage

Battery status

12,8V to 12,65V

The battery is fully charged.

12,6V to 12,4V

The battery is half charged.

< 12V

The battery is discharged.

  1. If the battery voltage is lower than 12V:

    Charge the battery

or

If the battery is not consuming any power:

Replace the battery.

IMPORTANT
Destruction of the generator when the battery is removed
Keep the fan switched off.
  1. If necessary to access the battery:

    Unfold the implement.
  2. Put the battery 2 in the holder.
  3. Install the battery holder 1.
  4. To prevent short-circuits:

    Install the positive terminal + first.
  5. Install the negative terminal -.
  6. If terminal covers are available:

    Put the terminal covers on the battery.