Converting 6 rows to 7 rows

For a row spacing between 60cm and 42,9cm, the fourth coulter is reactivated.

  1. Disconnect the ISOBUS from the tractor.
  2. telescope the implement in.
  3. Remove the linch pin 1 between the first and second coulter.
  4. Move the linch pin to the desired position between the first and second coulter.
  5. Move the opposite linch pin to the desired position between the sixth and seventh coulter.
  6. Remove the linch pin between the second and third coulter.
  7. Remove the opposite linch pin between the fifth and sixth coulter.

The implement is set to a row spacing of 70cm or 75cm.

  1. Telescope the implement out.

The second and sixth coulter are pushed 10cm outwards.

The inner telescopic rod 2 lies beside the 50cm pegging position 3.

  1. telescope the implement in.

The linch pin between the third and fourth coulter 4 is without tension.

The linch pin between the fourth and fifth coulter is without tension.

  1. Remove the linch pin 1 between the third and fourth coulter.
  2. Move the linch pin to the desired position between the third and fourth coulter.
  3. Move the opposite linch pin to the desired position between the fourth and fifth coulter.
  1. Remove the linch pin 1 between the second and third coulter.
  2. Move the linch pin to the desired position between the second and third coulter.
  3. Move the opposite linch pin to the desired position between the fifth and sixth coulter.
  4. Telescope the implement out.

The desired row spacing is adjusted between all of the coulters.

  1. To activate the fourth seeding coulter,

    disconnect the seeding coulter wiring harness 1 from the bridge plug 3.
  2. Connect the implement wiring harness 2 to the seeding coulter wiring harness 1.
  3. Seal the bridge plug with a dust cap.
  4. To lower the fourth seeding coulter,

    see Using the coulter raised position.
  5. Connect the ISOBUS to the tractor.
  6. Restart the implement.
  1. If the fertiliser metering unit was deactivated on the fourth row,

    open the sliding shutter 1 on the fertiliser metering unit of the fourth row.