Tensioning the V-ribbed belt

Interval

  • Drain 100 operating hours

    or

    Every 6 months

  1. Unscrew the lock nut 4.
  2. Place the torque wrench over the pivot point 2 on the clamping lever 1.
  3. Preload the clamping lever with the clamping torque.
  4. Mark the position of the clamping lever on the housing 3.
  5. Use the adjustment screw 5 to set the clamping lever to the determined position.
  6. Tighten lock nut.