Checking the oil level in the spur gear trough

Interval

  • After initial operation

  • all 50 Operating hours

    or

    Weekly

IMPORTANT
Damage due to impurities in the spur gear trough
Clean the implement before performing maintenance.
  1. Park the implement on a horizontal surface.
  2. Loosen and remove the nut 2.
  3. Remove the cover bolt 1.
  4. Remove the cover with ventilation pipe 4.
NOTE

If oil types are mixed, warranty claims cannot be accepted.

  • Do not mix oils.

  • Fill with new and clean gear oil.

  1. If the spur gears are not halfway covered with gear oil in the spur gear trough,

    refill oil according to the technical data.
  2. Check the fit of the gasket 3.
  3. Install the cover with the ventilation pipe.
  4. Install the cover bolt.
  5. Install the nut and tighten it.
NOTE

There is no need to change the oil in the spur gear trough.