Calibrating the metering unit of the micropellet spreader
To open the calibration flap 2:
Open the quick-release fastener 1.
To take the deflector plate 1 out of the holder:
Turn the deflector plate up until it can be guided through the slot 2.
To take the calibration flap 2 out of the holder:
Turn the calibration flap up until it can be guided through the slot 1.
- Attach the deflector plate 2 on the opening 1 of the tube.
The deflector plate 1 is in the calibration position.
The design of the calibration bucket can vary depending on the implement equipment.
- Take the calibration bucket 1 from the mount on the implement.
To collect the spreading material from the calibration:
Place the calibration bucket under the deflector plate.
To start the calibration:
Press the calibration button 1.
- Take the calibration scale 1 out of the storage bin and hang it on the weighing point.
- Hang the calibration bucket 2 on the scale.
To enter the weight of the collected spreading material on the control terminal or control computer:
Refer to the ISOBUS software operating manual, Calibration menu
or
refer to the Control computer operating manual.