Configuring the scale

If the scale is not working correctly, the scale must be tared and calibrated.

  1. Completely empty the hopper.
  2. Align the machine horizontally.
  3. In the Settings menu, select Service > Setup > Configure scale.
  4. Select Tare scale.

The theoretical hopper fill level will be displayed.

  1. Save values

or

Discard values.

  1. Select Calibrate scale.
  2. Continue.
  3. Fill the hopper. Fill quantity must be known.
NOTE
Minimum fill quantity: 1000
  1. Enter the filled quantity as the actual hopper volume.
  2. Continue.

The new calibration factor will be displayed.

  1. Save values

or

Discard values.